Command interface

The default server port for the command interface is port 8888. All commands and responses are in ASCII with lines separated by newline characters (ASCII character 0x0A).

All commands can be grouped into three forms (query, assignment, table assignment) and two targets (system and fields). There are exactly four possible response formats (ok, ok with value, error, multiple value). This section describes the command interface.

The three basic command forms are:

NameFormatDescription
Querytarget?Interrogates target for the current value; can return an error, a single value, or a list of multiple values.
Assignmenttarget=valueUpdates target with the given value; can return an error or success.
Tabletarget<formatCommand may be followed by lines of text, and must be terminated by a blank line.

The four basic command responses are:

NameFormatDescription
SuccessOKReturned by assignment and table commands to report a successful update.
ValueOK =valueSuccessful return of a single value from a query command.
ErrorERR errorError string returned on any command failure.
Multi value!value … .Any number of values can be returned, each preceded by !, finally . by itself indicates end of input.

Command forms and their possible responses:

FormResponses
QueryError, Value, Multi value
AssignmentError, Success
TableError, Success

Each individual query target will either return a single value or multi-value, as documented below.

Finally, there are two basic types of target: configuration commands and system commands.

Configuration commands

The entire hardware interface to PandA is structured into “blocks” and “fields”, and each field may have a number of “attributes” depending on the field type. This structure is reflected in the form of the configuration commands tabulated below:

Command syntaxDescription
block[number].field?Return current value of field.
block[number].field=valueAssign value to field.
block[number].field<[[<][|]][B]Write table data to field. < writes a fixed table, << writes a streaming table and <<| writes the last streaming table.
block[number].field.attr?Return current value of field attribute.
block[number].field.attr=valueAssign value to field attribute.
block[number].*?Returns list of fields.
block[number].field.*?Returns list of field attributes.

In all of these commands the number after the block is optional if there is only one instance of that block, and is ignored for the two .*? commands. See the description of the .TABLE fields in Blocks, fields and attributes for an explanation of the optional format characters in the table write command.

System commands

All system commands are prefixed with a leading * character. The simplest command is *IDN?, which returns a system identification string:

< *IDN?
> OK =PandA SW: 4.1-1-g2a34851 FPGA: 4.2.0 04e81f37 8a2b0249 rootfs: 2023.2+snapshot-bb27e6aef4dafd501bb5d72c95facd178c92dc48 (langdale)

The available system commands are tabulated here and listed in more detail below:

CommandDescription
*IDN?Device identification.
*ECHO string?Echo.
*WHO?List connected clients.
*BLOCKS?List device blocks.
*DESC.block.field[.attr]?
*DESC.block.field[].subfield?
Show description for field, attribute, or table subfield.
*ENUMS.block.field[.attr]?
*ENUMS.block.field[].subfield?
List enumerations for field, attribute, or table subfield.
*CHANGES[.group]?Report changes to values. group can be any of CONFIG, BITS, POSN, READ, ATTR, TABLE, or METADATA.
*CHANGES[.group]=[E|S]Reset reported changes; group as above.
*CAPTURE?Report fields configured for capture.
*CAPTURE.*?List all fields that can be captured.
*CAPTURE.name?Interrogate capture options; name can be OPTIONS or ENUMS.
*CAPTURE=Reset data capture.
*POSITIONS?Enumerate possible capture positions.
*BITS?Enumerate possible bit bus positions.
*VERBOSE=valueControl command logging.
*PCAP.field?Special position capture status fields. field can be any of STATUS, CAPTURED, or COMPLETION.
*PCAP.field=Position capture actions. field can be either ARM or DISARM.
*SAVESTATE=Triggers immediate save to file of the persistence file state.
*CLOCK_FREQ?Returns currently configured system clock frequency.
*IDN?

Returns the system identification string, for example:

OK =PandA SW: 1.1 FPGA: 0.1.9 d1275f61 00000000 rootfs: PandA 1.1

The first field after “PandA” is the software version, the second is the FPGA version, the third the firmware build number, and the fourth identifies the supporting firmware. The final fields (prefixed rootfs:) identify the underlying system on which the server is running.

Note that the rootfs: identification is new to version 1.1 of PandA.

*ECHO string?

Returns the string back to the caller. Not terribly useful. Note that the echoed string cannot contain any of ?, = or <, as this would cause the command to be mistaken for another command format. Example usage:

< *ECHO This is a test?
> OK =This is a test
*WHO?

Returns a list of client connections, for example:

< *WHO?
> !2015-12-04T14:30:40.403Z config 127.0.0.1:34185
> .

The first field is the time the connection was made, the second is either config or data depending on whether the configuration or data port is connected, and the third is the remote IP address and socket.

*BLOCKS?

Returns a list of all the top-level blocks in the system. The order in which the blocks are returned is somewhat arbitrary. For example (here the list has been shortened in the middle):

< *BLOCKS?
> !TTLIN 6
> !OUTENC 4
...
> !CLOCKS 1
> !BITS 1
> !QDEC 4
> .

Block and field commands can be used to interrogate each block. The number after each block records the number of instances of each block.

*DESC.block?
*DESC.block.field?
*DESC.block.field.attr?
*DESC.block.field[].subfield?

Returns the description string for the specified block, field, attribute, or table subfield, e.g.:

< *DESC.TTLIN?
> OK =TTL input
< *DESC.TTLIN.TERM?
> OK =Select TTL input termination
< *DESC.TTLIN.TERM.INFO?
> OK =Class information for field
*ENUMS.block.field?
*ENUMS.block.field.attr?
*ENUMS.block.field[].subfield?

Returns the list of enumerations for the given field, attribute, or table subfield, if appropriate.

*CHANGES?
*CHANGES.CONFIG?
*CHANGES.BITS?
*CHANGES.POSN?
*CHANGES.READ?
*CHANGES.ATTR?
*CHANGES.TABLE?
*CHANGES.METADATA?

Reports changes to the appropriate group of values. Changes are reported since the last request on the connection, and on the first request the current value for every field will be reported. *CHANGES? reports changes for all groups; otherwise one of the following groups can be selected:

GroupDescription
CONFIGConfiguration settings
BITSBits on the system bus
POSNPositions
READPolled read values
ATTRAttributes (including capture enable flags)
TABLETable changes
METADATAMetadata field changes

For example:

< *CHANGES.CONFIG?
> !TTLIN1.TERM=High-Z
> !TTLIN2.TERM=50-Ohm
> !TTLIN3.TERM=High-Z
...
> !QDEC2.B=TTLIN1.VAL
> !QDEC3.B=TTLIN1.VAL
> !QDEC4.B=TTLIN1.VAL
> .

Here 804 (at the time of writing) lines have been deleted from the transcript. If we repeat the call we see that no further changes have happened until something is actually changed:

< *CHANGES.CONFIG?
> .
< TTLOUT4.VAL=TTLIN3.VAL
> OK
< *CHANGES.CONFIG?
> !TTLOUT4.VAL=TTLIN3.VAL
> .

Note that for tables only the fact that the table has changed is shown; no attempt is made to show the current table value:

< *CHANGES.TABLE?
> !PCOMP1.TABLE<
> !PCOMP2.TABLE<
> !PCOMP3.TABLE<
> !PCOMP4.TABLE<
> !PGEN1.TABLE<
> !PGEN2.TABLE<
> !SEQ1.TABLE<
> !SEQ2.TABLE<
> !SEQ3.TABLE<
> !SEQ4.TABLE<
> .
*CHANGES=[E|S]
*CHANGES.CONFIG=[E|S]
*CHANGES.BITS=[E|S]
*CHANGES.POSN=[E|S]
*CHANGES.READ=[E|S]
*CHANGES.ATTR=[E|S]
*CHANGES.TABLE=[E|S]
*CHANGES.METADATA=[E|S]

These commands reset the change information for the corresponding group so that only changes occurring after the reset are reported, or so that all changes are reported. If = or =E (for End) is specified then only new changes are reported; if =S (for Start) then change reporting is reset to the start as for a new connection. For example:

< TTLIN1.TERM=50-Ohm
> OK
< *CHANGES=
> OK
< *CHANGES.CONFIG?
> .
*CAPTURE?

Returns a list of all positions and bit masks that will be written to the data capture port. This list is controlled by setting the .CAPTURE attribute on the corresponding position fields.

*CAPTURE.*?

Returns a list of all fields that can be configured for capture. This includes all pos_out and ext_out fields.

*CAPTURE.OPTIONS?

Lists the available capture options for pos_out fields. See Capture options for the full set of options.

*CAPTURE.ENUMS?

Generates a curated list of capture option selections, designed for presenting lists of available capture options as an enumeration. Returns the same as calling *ENUMS.name.field.CAPTURE? on any pos_out field.

*CAPTURE=

Resets all .CAPTURE flags to zero so that no data will be captured.

*POSITIONS?

Lists all available position capture fields in order.

*BITS?

Lists all available bit bus positions, but not including the special values ZERO and ONE.

*VERBOSE=value

If *VERBOSE=1 is set then every command will be echoed to the server’s log. Set *VERBOSE=0 to restore normal quiet behaviour.

*PCAP.STATUS?
*PCAP.CAPTURED?
*PCAP.COMPLETION?

Interrogates the status of position capture:

FieldDescription
STATUSReturns a string with three fields: “Busy” or “Idle”, followed by the number of connected readers, and the number taking data.
CAPTUREDReturns the number of samples captured in the current or most recent data capture.
COMPLETIONReturns the completion status from the most recent data capture, as listed in the table below.

The completion codes have the following meaning:

CodeMeaning
BusyCapture in progress.
OkCapture completed without error or intervention.
DisarmedCapture was manually disarmed by *PCAP.DISARM= command.
Framing errorData capture framing error, probably due to incorrectly configured capture.
DMA data errorInternal data error, should not occur.
Driver data overrunData capture too fast, internal buffers overrun. Can also occur if the PandA processor is overloaded.
*PCAP.ARM=
*PCAP.DISARM=

Top-level capture control:

FieldDescription
ARMInitiates data capture. Will fail if capture is already in progress, or no fields are configured for capture.
DISARMHalts ongoing data capture.
*SAVESTATE=

Updates the persistence state file (as configured on the command line when launched) with the current state. Returns after a filesystem sync call, so it is safe to power off the system after this command has completed.

*CLOCK_FREQ?

Returns the currently configured FPGA clock frequency, as used to convert between times in natural units and times in clock ticks.